Masonry construction
Ridge Lines
This article provides a practical overview of masonry construction, examining the materials, structural forms, movement characteristics, design standards and detailing principles that govern modern masonry buildings. It will be particularly useful for legal practitioners seeking to better understand how masonry systems function, why defects develop, and where design and construction issues commonly arise. By understanding how masonry systems are intended to function, legal professionals will be better equipped to evaluate expert evidence, identify potential liability issues, understand causation arguments and navigate the technical aspects of construction disputes and insurance claims involving masonry structures.
Masonry construction
Overview
Masonry is one of the oldest building materials, dating back thousands of years. Its widespread availability, straightforward production process and durability led to its adoption in most parts of the world, and many of these buildings are still with us. The formation of structures using small individual units such as bricks, concrete blocks, or stone, bonded together with mortar, is highly adjustable and interfaces easily with other forms of structure. As a result, masonry became the most common construction for residential buildings in most parts of the world. To this day, masonry construction remains one of the most enduring and popular forms of construction.
Properties
Masonry encompasses brick, concrete blocks, stone, and the various forms of mortar that bond the units together. However, a feature they all have in common is that the material is strong, durable, and fire-resistant.
Bricks are typically made from clay, which has been formed and then fired at temperatures up to 1100°C. Less commonly, they can be made from calcium silicate, essentially sand and lime, which are more commonly used in Europe, Australia and Africa. The three main forms of brick are common bricks, facing bricks and engineering bricks. Common bricks are the most basic, being low strength and inconsistent in colour. As a result, they are typically used for internal applications. Facing bricks are consistent in colour and are typically used for external walls where aesthetics is important but high strength is not required. Engineering bricks have a high compressive strength, combined with resistance to frost and water ingress. They are often used in high stress areas of structure, as well as in damp underground situations such as tunnels and foundations.
Concrete blocks, as the name implies, are made from concrete in various forms. They are similar in nature to bricks but two to three times larger and thus quicker to construct. These tend to be used for internal walls or rendered external applications.
Stone is a very ancient building material comes in many formats. The most used stones for construction in the UK include sandstone, granite, limestone, and slate. The traditional load-bearing application of stone gave way to cladding-type uses in the 20th century, but with its low embodied carbon, and innovations like post-tensioned stone structure, load-bearing stone is expected to make a comeback.
Both stone and brick have comparable thermal expansion coefficients to steel and concrete; around 10 to 12×10–. A 10m length of wall subjected to a ±20°C change in temperature will move ±1.6mm. Movement joints are required at intervals to accommodate this movement, as discussed further below.
Masonry Strength
Masonry strength varies enormously depending upon type, density, production method and constituents. Concrete blocks can have strengths from as low as 3 MPa up to 40 MPa, although strengths above 15 MPa are rarely used in practice. Correspondingly, densities can range from 1000 to 2000 kg/m3.
Bricks can have strengths from as low as 7 MPa for common brick up to 125 MPa for engineering brick. Facing brick in external walls would commonly be stronger than 20 MPa. Correspondingly, densities can range from 1600 to 2000 kg/m3.
As a natural material, stone has a wide range of strengths and densities depending on the rock type. Strength can range from 20 MPa for soft limestone up to 350 MPa for a hard basalt. Densities typically range from 2300 kg/m3 for limestone up to 3000 kg/m3 for basalt.
Masonry Sections
Masonry comes in many formats, the most basic being standard brick and concrete block dimensions. These two are typically used in combination as the outer and inner leaves of a cavity wall. For this reason, the concrete block dimension is a multiple of the brick dimension. The block is three times the height of a brick and twice as long when a 10mm mortar joint is added, ensuring that inner and outer joints always coincide between the two leaves and thus allowing for ties, lintels, and openings to easily interface at one point. Other unit sizes are available, but these need to coordinate joint locations. The size and density of blockwork is frequently dictated by limitations on manual lifting.
Stone sizes can be more variable but as a denser material even than concrete, lifting equipment is frequently used as a result. Another solution to this problem is to use the stone as a veneer, a form called ‘ashlar’ construction, where stone of 15-30 mm thickness will be supported by a backing wall or frame to give the appearance of a stone façade. Up until the mid-20th century, full thickness stone blocks were often built interlocking with a brick backing in a stepped format, providing the required thickness of wall but using less stone in lieu of brick.
Mortar types
Mortars have also developed in conjunction with masonry construction. Most buildings up until the 20th century would have used lime mortar, made from lime, sand and water. It does not fully harden so retains a degree of flexibility during its life, which means that walls with this type of mortar can tolerate some movement without cracking. Lime mortar is also breathable, so it was suitable for solid walls without cavities, with the mortar allowing the wall to expel moisture over time.
Modern mortars are now typically based on Portland cement, sand and water. These developed in tandem with cavity wall construction, where moisture was positively drained within the cavity and expelled via perpend drains at the bottom of the cavity. Thus, the mortar did not need to be breathable in the same way as lime mortar. Cement-based mortars are stronger than lime but less flexible and permeable. As a result, these tend to crack with movement and trapped moisture can become more problematic.
Structural forms
Masonry construction was traditionally load-bearing in nature, taking floor loads from upper floors down to foundation level via the walls. As buildings increased in height, load-bearing walls became challenging due to the increasing thickness of walls to avoid instability. Although load-bearing stone monuments such as the Washington Monument reach as high as 169 m, the practical limits of a load-bearing masonry building with habitable floor space reached a maximum of 60 m for the Monadnock office building in Chicago.
Hybrid forms developed in the 19th and 20th centuries, such as steel frames built into load-bearing façades, a form of construction that was popular for many Portland stone buildings in the City of London from that era. This has the advantage of allowing the steel frame to progress rapidly, with the masonry façade following behind.
Most masonry construction was formed of solid walls up until the 20th century, both for brickwork and stone, so no cavity was present to provide insulation or drain moisture. The first cavity construction was used in the 1820’s in Liverpool and was more common in coastal areas where driving rain was an issue. From the mid-1900’s, cavity construction increasingly became the norm in the UK. The major advantage of cavity construction is the ability to insert insulation and to positively drain moisture. This led to better energy efficiency in buildings as well as better moisture management.
However, a negative impact of cavity wall construction is that the load-bearing capacity of walls was limited to the inner leaf only and was thus very much lower than a solid wall. For multi-storey buildings, the outer leaf also has to be supported by the main frame, requiring the frame itself to be more substantial and costly. This in turn leads to the common occurrence of excessive frame deflection causing cracking or damage to the façade. This is still a common defect encountered in modern construction.
When horizontal wind-load is applied to a cavity wall, for economy of materials, it makes sense for both leaves to act together to resist the load. This requires the two leaves to be joined with steel ties, which ensures that both leaves share the load, as well as tying them together to avoid instability.
Some panels of masonry wall have limited resistance to horizontal load in particular, because they do not perform well in bending. Windposts can be added to provide lateral support to the wall, which are spaced at appropriate centres to support the entire length of a wall.
The outer leaf in cavity construction is typically supported by the main frame behind. This support is provided by a stainless or galvanised steel angle connected to the main frame, often at every floor or alternate floors. This generates the need for horizontal movement joints below these angles to accommodate the expansion and contraction of the panel below.
In recent years, load-bearing stone and brick is making a comeback for medium-rise non-residential buildings. This is mainly driven by the low-carbon characteristics of these materials. However, due to the lack of industry knowledge in detailing of load-bearing façades (e.g. moisture management, condensation, insulation, etc.), this development may be problematic in future.
Joints
Masonry expands and contracts with temperature and, in some cases, with moisture. Like the base material, concrete bricks and blocks can also shrink to a small degree over time. At the same time, the supporting structure is also subject to movements from temperature, settlements, axial shortening[CC2.1] of columns due to loading, sway, etc. This generates a complex combination of daily, seasonal and progressive movements that can often be underestimated by designers and detailers. In load-bearing masonry, the load on the masonry can act as a form of restraint to movement, so these can potentially require fewer joints. Likewise, older masonry buildings with lime mortar can tolerate these movements to a good degree, so seldom had joints like modern structures.
Table 1 – recommended joint spacing in masonry (Local Authority Building Control).
| Material | Joint Spacing (m) | Joint width (mm) |
| Clay brick | 12 m | 15 mm |
| Calcium silicate brick | 7.5 – 9 m | 10 mm |
| Concrete brick | 6 m | 10 mm |
| Concrete blockwork | 6 m | 10 mm |
| Natural stone masonry | 15-20 m | 10 mm |
In contrast, most modern buildings with the external leaf supported by the frame will require movement joints at regular spacings to avoid damage from movements. Brick and block panels can expand around 1 mm per metre of length, so a 6 m long panel may move up to 6 mm. The materials within the joint can accommodate 50% compression without damage, so are generally formed wider than the anticipated movement, e.g. a 6 m panel would typically have a 10 mm joint to accommodate the movement without damage. Although industry guidance such as Eurocodes does recommend joint spacings, they defer to guidance from the manufacturer due to the variation in material properties.
Unfortunately, the complexity of combined movements of masonry and the supporting frame leads to frequent underestimation of the joints required. Two common examples are parapets and first floor joints. In the case of a parapet, these are often formed with concrete upstand beams, making the roof slab more rigid than the floors below, which deflect to a higher degree. Hence, a gap may open up in the joint under the roof slab and tear the joint material. Masonry built off the ground or foundations will typically not be subject to the same frame deflection that occurs on upper floors, creating a differential deflection. Hence, the joint at first floor often closes more than upper floors and is often underestimated in terms of thickness.
Design and Specification
The design of masonry in the UK and EU is governed primarily by Eurocode 6 (BS EN 1996-1 Design of masonry structures), which replaced the previous British Standard BS 5628 in 2010 (see article 2). Some of the commonly used codes for masonry include:
- BS EN 1996 (Eurocode 6): Design of Masonry Structures
- Part 1-1: General rules for reinforced and unreinforced masonry.
- Part 1-2: Structural fire design.
- Part 2: Materials and workmanship.
- Part 3: Simplified calculation methods for unreinforced masonry.
- BS EN 771 series: Specifies requirements for masonry units:
- BS EN 771-1: Clay bricks.
- BS EN 771-3: Concrete blocks.
- BS EN 771-6: Natural stone masonry units.
- BS EN 998 series: Mortar specifications:
- BS EN 998-2: Masonry mortar.
- BS EN 845 series: Ancillary components (ties, straps, etc.).
- BS EN 1990 & BS EN 1991: Basis of structural design and loading (used alongside Eurocode 6).
The previous British Standard ‘BS 5628: Code of practice for the structural use of masonry’ was withdrawn in 2010. That was based on permissible stress design (ensuring the actual stresses a material experiences under normal service loads never exceed a safe ‘permissible’ limit), whereas Eurocodes are limit state design with ultimate and serviceability limit states (which uses various factors to increase the loads and reduce material strengths to ensure the design of the structure never exceeds the ‘ultimate’ limit i.e., collapse or failure). NHBC Chapter 6.1 for masonry construction is still applicable as most residential dwellings are still formed with brick facades.
The engineer’s design is usually accompanied with a specification, which defines details about the grades of masonry, mortar, tolerances, etc. Although a designer may produce their own bespoke specification, the industry standard template is the National Building Specification (NBS), an entire suite of specifications for many materials and components published by NBS.
Procurement
Masonry is frequently split in terms of design responsibility. Where it is used in load-bearing applications, design responsibility typically falls within the remit of the structural engineer. Where it is non-load-bearing, it is usually sub-contractor designed. In this circumstance, the engineer may provide generic details (ties, restraints, windpost spacing, etc.) which are expected to be incorporated by the sub-contractor, but the latter is responsible for detailed design and applying the appropriate details for joints, ties, wind-posts and ancillary materials.
The external leaf of masonry façade is typically detailed either by the architect, sometimes with input from the façade engineer, the latter picking up some of the more technical aspects such as detailing of membranes, fixings, cavity barriers, joints, etc. The various interfaces that occur in facade design mean that a good level of coordination is required between the architect, façade engineer and structural engineer. This is perhaps most apparent at joints in brickwork, where the structural engineer may recommend joint spacing and locations, the architect may incorporate (or alter) this information on their drawings, and the façade engineer may offer some detailed input. Joint thicknesses are rarely addressed in significant detail as the ultimate responsibility for detailing of them is not always clear and there is a lack of appreciation in the industry on how these are intended to function.
Drawbacks
The two largest issues facing masonry construction are an industry lack of expertise in detailed design, and the complex combination of movements with their associated joint requirements.
In engineering terms, few engineers or architects are highly proficient in the design and detailing of masonry. For example, it is rare that an engineer will carry out a rigorous analysis of the combined movements of structure and masonry, much less consider these at various points around the building. This leads to the frequent under-specification of joints by the architect in many buildings, with an almost universal provision of 10 mm joints for aesthetic reasons rather than performance.
The sometimes-vague interface of responsibility for façade detailing between architects, structural engineers and façade engineers commonly leads to a situation where no practitioner is willing to take responsibility for showing the coordinated details on their drawings, leaving a contractor poorly informed on what to construct.